SLIDING GATE
sliding gate operator
1. Functions
1). The structure of integrated mechanic and electric, without any other controllers
2). Electronic soft-start
3). With crashworthy and self-backtrack interfaces
4). Automatic return for resistance
5). Photocell
6). Line control
7). with interface for flashing lamp
2. Motor Data
Model: KMP 202
Voltage: 220V±10%
Frequency: 50/60Hz
Current: 2.7A, 5.8A
Motor voltage: AC 220V
Capacitor: (220V) 20uF, 60uF+14uF
Power: 350W
Torque: 35nm
Motor number: M=4
Motor speed: 1620rpm
Gear speed: 70.2rpm
Travel speed: 11m/min
Working temperature: -40°c~ 55°c
Overload protection temperature: 130
Relative humidity: =<90%
Motor making technique: die casting aluminum alloy
Manual Release: yes
Remote distance: => 30m
Product weight, approx: 10.19kg, 10.25kg
Max, weight of gate: 1500kg
3. Electronic Data
Model: KMP202
Soft start: YES
Stop on obstacle (sensitivity adjustable): YES
Auto warming-up (at freezing temperature): YES
Remote control: 418MHz (50m, approx)
Wire control: Available
Auto closing: YES
Vehicle loop detector socket: YES
Photocell socket: YES
Alarm light socket: YES
Packing list
Name Qty Unit Remark
Sliding gate operator 1 Set
Rem ote controller 2 Pcs
Internal hexangular bolt 4 pcs M8X40
Internal hexangular bolt 4 pcs M6X16
Left limit iron 1 pcs
Right limit iron 1 pcs
Base 1 pcs
Release Key 2 pcs
Manual 1 pcs
SWING GATE
SWING GATE OPENER TECHNICAL PARAMETERS
Input Voltage: 24VDC 40W
Rotational Speed:250RPM
Rod's Running Speed:1.6cm/s
Rod's Max Travel:300mm
Continue running time: 5min
Max Single-leaf Length:2.5m*2
Travel Max Single-leaf Weight:300KG
GEnvironment Temperature:-20°C~+50°C
Protection Calss:IP55
Functions and testing:
1. Indicator LED light: It’s always on once the system electrified.
LED indicator for “auto-closing”flashes every 1second. It turns off
when enter into the learning code state or removing code state; it
flashes twice after successfully learning code or removing code.
2. Transmitter : using our company own customed rolling code.
Singe-leaf button controls opening and closing of MOTOR2, double-leaf
button simultaneously controls
opening and closing of MOTOR1 & MOTOR2. The control panel can memorize 20 transmitters at most.
3. Code-learning: press and hold learning button for 1second then
release, LED turns off and press any button of transmitter, then LED
flashes twice, now the codes has been learnt to the panel. If there is
no any signals received within 5seconds, the LED will light and then exit code-learning state .
4. Code-removing: press and hold learning button (once you press
learning button,LED is off), 5seconds later LED lights up, now the codes
has been removed.
Tidak ada komentar: